IM12-150W iManager wireless battery management - onboard energy

NDS DOMETIC
Your price:
€ 248,00
Price per single item (VAT included)
In stock, ready to ship
Calculating shipping costs to

NDS has designed and created iManager Wireless the manager of batteries and onboard energy requirements, the result of continuous research and experience gained with Power Switch and Energy Meter.

This version allows wireless communication between the control unit and display (no connection cables), the display will simply be powered with a +12V.

iManager allows you to manage up to three batteries simultaneously, or separately, even with different technologies and amperages, improving their performance and thanks to the automatic battery disconnect function, it preserves their life.

iManager - Main Functions:

• Automatic or manual management of one or two service batteries, even of different technology and amperage

• Dedicated output for charging the engine battery, when the service batteries are 100% charged (e.g.: storage)

• Displays the charge status of the accumulators

• Displays voltage and Amperes of charge and discharge

• Automatic battery disconnect (below 11V) or manual, via Touch display

• Display of information and advice on battery management and maintenance

• Date and time

• Temperature control during charge/discharge phases, for greater safety
iManager operates constantly monitoring the voltages of the two batteries and taking into account the charge and discharge currents, it automatically decides and selects the battery to be used, with the goal of keeping them always at the same charge level to optimize their performance.
iManager thanks to the touch display displays all available information, both on the charge status of the accumulators and the usage modes, allowing with a simple touch, to manually select the batteries to activate or deactivate, for more personalized management.
iManager also has a dedicated output for the engine battery; the system when it detects a charging source (mains battery charger or solar panel) on the service batteries and these are at 100%, provides a maximum current of 4 A to the engine battery to keep it charged, thus avoiding unpleasant surprises when restarting after long stops.
Many are the functions, among the most important that of automatic battery disconnect, which is activated in three different cases:

• When the voltage of one or both batteries drops below the critical limit of 10.5V

• When the voltage of one or both batteries remains below 11V for more than 15 minutes

• When the temperature measured on one or both batteries exceeds the limit threshold of 70°
In this way, loss of efficiency or irreversible damage is avoided.