CF0044UNUN31 FIREWALL OBD2

Paser
Your price:
€ 122,00
Price per single item (VAT included)
Calculating shipping costs to

Paser CF0044UNUN31 Firewall OBD2, electronic alarm against OBD2 port tampering attempts

FIREWALL OBD2 is a car alarm that stands between external devices and the vehicle's communication BUS, preventing any unauthorized access to system configuration data.

Through the use of key duplicators and OBD access, it is possible for a malicious actor to generate new vehicle access codes in a few seconds, excluding the alarm device present. FIREWALL OBD2 protects the vehicle by making this impossible!

Features and operation

FIREWALL OBD2 connects via a Plug & Play cable to the OBD2 connection by replicating the port and thus maintaining unchanged operation on the vehicle. Access to diagnostics will always be possible under normal conditions but blocked in anti-theft mode.

FIREWALL OBD2 is able to operate in "stand alone" mode, through a remote control (optional) or in combination with the alarm system installed on the vehicle, automatically activating the data protection function when the anti-theft is armed.

FIREWALL OBD2 automatically switches to low power mode when there is no activity on the bus, reactivating real-time data passage as soon as required. In the condition of active protection, data passage to the vehicle system is never allowed.

FIREWALL OBD2 is easily programmable via a button and a multicolor LED positioned on the front part.

The LED shows the module status:
RED: ACTIVE >> the CAN bus line cannot be reached via the OBD port in its socket
GREEN: NOT ACTIVE >> the CAN bus line is reachable
YELLOW: the module is in configuration mode

When FIREWALL OBD2 is connected to the OBD port as shown in the diagram on the next page, on first use, the status is "ACTIVE" (RED LED).
Via the configuration menu it is possible to pair one or more radio frequency remote controls to the module.


FIREWALL OBD2 can be managed by an existing alarm system installed on the car by connecting the command cable to the reference output of the alarm unit.
Using the configuration menu it is possible to choose the reference level of the command signal (GND Reference or Vcc).
It is also possible to select the activation status for the selected signal (Activation ON or OFF), the number (1 or 3) of activations and management via wire/remote control or remote control only.

When an external alarm is connected, its activation command takes priority over the remote control.

When the configuration procedures have been completed, it is necessary to disconnect and reconnect the module so that it becomes operational.

BUZZER:
long sound >> Active | 2 short sounds >> Not Active

Manuale utente

n-20170405155800-firewall-1-0-16-ita.pdf
€ 122,00 Price incl. VAT